RFI from Accurange3000 distomat
Links:
20apr11:rfi on telescope using 327 rcvr
accurange3000 distomat.
06apr11:rfi from accurange3000 distomat in screen
room.
Accurnage3000
distomat hardware page
20apr11: rfi on telescope using 327 rcvr. (top)
The rfi from the Accurange3000
distomat
was tested on 20apr11. The setup was:
- accurange3000 at distomat 1 position (about azimuth 35) along rim
road. Shooting up to reflector on corner 12.
- mock spectrometer, 1 second dumps to record spectra. 172 MHz
- 327 rcvr. sitting
- lbw rcvr: 4 bands covering 1120 to 1750.
327 test:
The power on,off sequence was:
-
327 laser actions
sec |
Action
|
0 |
All off
|
146
|
PowerSupply, laser on
|
246
|
All Off |
458
|
PowerSupply, laser on |
524
|
All Off
|
The dynamic spectra show the on,off sequence (dashed horizontal lines):
lbw test:
The power on,off sequence for lbw was:
-
lbw laser actions
Sec
|
Action
|
0
|
All off |
75
|
PowerSupply,laser on
|
150
|
All off
|
208
|
PowerSupply on |
248
|
PowerSupply,laser on |
299
|
PowerSupply on |
342
|
All off |
The dynamic spectra show the on,off sequence (dashed horizontal lines):
Summary
- There are no obvious rfi that follow the on,off pattern
used for the distomat
- The images have used a decimate by 6 to display the 8192 channels.
processing: x101/110420/chkdistnew.pro
06apr11: rfi from accurange3000 distomat in
screen room.
The accurange
3000 distomat was being tested
to replace the laser rangers. On 06apr11 an accurange 3000 laser was
tested by luis quintero
in the screened room using a probe and
spectrum analyzer. The setup was:
- Accurange 3000 sitting out in the screen room (no huffman
box).
- agilent E4445A spectrum analyzer, 601 channels, and preamp on.
- 1 MHz to 10 Ghz. I've included the data from DC to 6 gHz.
- ETS model 7405 probles:
- 902:magnetic field. resonant freq 1.5 Ghz
- 903:magnetic field. resonant freq 2.3 Ghz
- 904:electric field: resonant freq > 1Ghz
- Move the probes around the device looking for maximum value
(spectrum analzyer set to max hold).
The plots show the results
of the measurements (.ps) (.pdf):
- Page 1: 902 probe, 0 to 1.5 Ghz.
- top, middle, bottom are 500 MHz sections of 0 to 1.5 Ghz.
- Each color is a separate measurment with the spectrum analyzer.
- some of the spectra have a lower noise baseline. These have
narrower resolution bandwidths.
- The dotted vertical lines are a comb ath 36.8789 MHz
- The strongest comb birdies are at:
- 295.031 MHz : -66dbm. This repeats for different measurements.
- 1032.61 MHz : -71dbm, 1069.49 MHz : -74dbm
- Page 2: 902 probe 1.5 Ghz to 6 Ghz
- top,middle, bottom are 1.5 Ghz sections from 1.5 to 6 Ghz.
- There are no obvious birdies that stick out (but these
resolution bandwidths are pretty wide.
- Page 3: compare the response of the 3 probes:
- the colors correspond to the different probes:
- black probe 902 (res freq 1.5 Ghz).
- red probe 903 (res freq 2.3 Ghz)
- green Electric field > 1Ghz.
- probe 902 and then 903 do the best job showing the comb. 904
does not see things above 300MHz.
- this test does not guarantee that the positions of the 3 combs
were exactly the same.
Summary:
- The accurange3000 has a comb with a spacing of 36.8789 MHz
- we saw the comb with the probes up to about 1100 MHz.
- The strongest comb elements are:
- 295.031,1032.61,1069.49 MHz.
- probe 902 does the best job showing the probe up to 1.5 Ghz.
processing: x101/110406/dolaser.pro