Measured operating values

23oct15

  
The table below contains the measured meter and drive values while tx's were in use.

Columns/abbreviations:


expected meter values when running at 100KW (from manual)

dates:

Notes:



To add more entries: edit and insert (vi) operating_value_template_insert.html at commented insertion point.
pink color is : Value out of specified range



tx
otx

date
S/D


drv
dbf
pwr

RP
FP/
RP
BB
W
Tube
elements

IPA DRVR
PA
KW
dbm
V
I
V
I
V
I
5


151021
dmyLd



-3.6
90



16.8



Fila V/A          
         
        
         
        
         
cGrid V/mA



-300

scrGrid mA xx

xx

xx

cath A xx

xx

xx
18.4
 
5



151022
sky



-3.25
83



16.5
30
25.
225
Fila V/A        
        
       
        
       
        
cGrid V/mA



-380?

scrGrid mA xx

xx

xx

cath A xx

xx

xx
15
 
1

15
151022
sky



-7
87



16.7
35
23.
122
Fila V/A        
        
       
        
       
        
cGrid V/mA



-300

scrGrid mA xx

xx

xx

cath A xx

xx

xx
12
 
4

145
151022
sky



-6
80



16.3
66
12
60



Fila V/A
       
        
       
        
       
        
cGrid V/mA




-300

scrGrid mA
xx

xx

xx

cath A
xx

xx

xx
14
151026 no rf drive 
1



151026



0
0



0 0 0 0 Fila V/A   6.8 
70
6.3  
190
8
75 
Grid V/mA -240
10
-240
12
-295
20
scrGrid mA xx
6
xx
10
xx
0
cath A xx
.7
xx
0
xx
0
 
2



151026



0 0



0 0 0 0 Fila V/A 6.7
60
5.8
150
14
175
cGrid V/mA -270
0
-250
0
-300
0
scrGrid mA xx
4
xx
0
xx
0
cath A xx
2
xx
.4
xx
3.5
 
3



151026



0 0


0 0 0 0 Fila V/A 6.6
70
6.2
150
13.5
210
cGrid V/mA -280
0
-265
0
-295
0
scrGrid mA xx
3
xx
0
xx
0
cath A xx
0
xx
.6
xx
2
 
4



151026



0 0



0 0 0 0 Fila V/A    6.3
60
6.4
195
14
   240
cGrid V/mA -300
3
-270
3
-360
0
scrGrid mA xx
9
xx
1
xx
0
cath A xx
.1
xx
.4
xx
3
 
5



151028



0 0



0 0 0 0 Fila V/A  6.3
75
6.4
215
14.5
240
cGrid V/mA -280
2
-280
0
-310
badsw
scrGrid mA xx
5
xx
10
xx
0
cath A xx
.2
xx
.5
xx
4
 
6



151026



0 0



0 0 0 0 Fila V/A  6.8
50
6.5
140
15
250
cGrid V/mA -280
+100
-280
+100
-360
4.8
scrGrid mA xx
3
xx
0
xx
10
cath A xx
.7
xx
.2
xx
0
 
3
(1)

151027
dmyLd
-3
dbf
57
KW



14.82
dbm
1
50/1
200
Fila V/A        6.6
70
6.1
140
13.5
210
cGrid V/mA -260
0
-270
0
-320
0
scrGrid mA xx
27
xx
50
xx
50
cath A xx
0
xx
3
xx
13
 
3
(1)


151028
dmyLd



-3.6
86
88



16.65
16.75
1
85/1
158
Fila V/A        6.8
70
6.2
150
13.5
210
cGrid V/mA -250
0
-240
0
-310
110
scrGrid mA xx
27
xx
70
xx
100
cath A xx
0
xx
3.6
xx
15
 

















Fila V/A          
         
        
         
        
         
cGrid V/mA





scrGrid mA xx

xx

xx

cath A xx

xx

xx

 

















Fila V/A          
         
        
         
        
         
cGrid V/mA





scrGrid mA xx

xx

xx

cath A xx

xx

xx



Daily Notes:
Measured filament voltage and % error from optimum value
tx
ipa 
(range 7.13-7.87)V
CurA
60-90
drvr
range (6.0-6.6 V)
curA
140-180
PA 
range (14.75-16.25)
curA
195-235

MeasuredV
% error
measured
% error
measured
% error
1
6.8
10.3
70
6.3
0
190
8.0
93.8
75
2
6.7
11.9
60
5.8 8.6
150
14
10.7
175
3 6.6
13.6
70
6.2
1.6
150
13.5
14.8
210
4
6.3
19.0
60
6.4
1.6
195
14.0
10.7
240
5
6.3
19.0
75
6.4
1.6
215
14.5

240
6
6.8
10.3
50
6.5
3.1
140
15.0
3.3
250

page up
home_phil