C1 | from | to | description |
1 | PA.1 | P8.1 | vertex datataking ethernet rx @ pntp1 |
2 | PA.2 | P8.2 | vertex datataking ethernet tx @ pntp1 |
3 | ocu.rx | lcu.tx | lcu to ocu rs422 link |
4 | ocu.tx | lcu.rx | lcu to ocu rs422 link |
5 | PB.11 (PA.3) | P8.5 | pnt crate irig board to lcu irig board. (PB.11 till PA.3 fixed)16feb03 |
6 | PA.4 | P6.1 | turret 485 link. rx @ pnt |
7 | PA.5 | P6.2 | turret 485 link. tx @ pnt |
8 | PA.6 | P6.3 | tertiary ethernet (datataking). rx@pnt |
9 | PA.7 | P6.4 | tertiary ethernet (datataking). tx@pnt |
10 | PA.8 | P6.5 | 1 pps for turret and tertiary (splitter in B13) |
11 | hpib extender |
28sep17 .. was platform ethernet RP1.6 to RP2.12 this fiber has 5db more loss than fiber 12 and 13 (so we switched to 13) |
|
12 | PA.10 | RP2.11rx | platform ethernet RP1.5 to RP2.11 (dewar monitoring) |
13 | PA.9 | RP2.11tx | platform ethernet RP1.5 to RP2.11 (was c1-11) (dewar
monitoring) |
14 | rcvrB |
P4.6 | from back of caldriver box (above box 1) this drives both
cals(check order 4.5,4.6) |
15 | rcvrA |
P4.5 | from back of cal driver box (not used) |
16* | 430 console |
p9-6 |
sband power meter.. power on,off |
17* | bad was hpib extender |
was p4.1 |
was hpib extender for datataking gpib switched to c.11 28sep17 |
18 | hpib | P4.2 | hpib extender for datataking gpib. checked 28sep17 |
19 | aonet |
c8.? |
vertex temperature sensor ethernet |
20 | aonet |
c8.? |
vertex temperature sensor ethernet? |
21 | 430console |
p9-2 |
sband power meter usb extender |
22* | 430console |
p9-3 |
sband power meter usb extender |
23* | pinched in fiber was P9-4 see 31 |
was b2 c7.1 |
was ch1 monoplexor driver |
24* | pinched in fiber was P9-5 see 32 |
was b2, c7.2 |
was ch1 monoplexor ack |
25 | Note |
dome |
dome video cameras. From controller at operators desk to
video box in tx room dome. |
26 | 430chLoblank |
b7.9 |
temp fiber for 430ch tx lo blanking whencable 12
damaged (04nov13) |
27 | free |
was hpib seti tx @ ctrlroom | |
28* | sbtx phase shifter was 430con |
?? was p6.12 |
sb tx phase shifter to balance the 2 klystrons was 430 pwr meter for greg dome (usb extender) |
29* | sbtx phase shifter was 430con |
?? was p6 ? |
sb tx phase shifter to balance the 2 klystrons was 430 pwr meter for greg dome (usb extender) |
30* | sbtx phase shifter was 430Con |
?? was p6? |
sb tx phase shifter to balance the 2 klystrons was 430 pwrmeter for greg dome (on/off for pwrmeter) |
31 | P9-4 | b2 c7.1 |
ch1 monoplexor driver |
32 | P9-5 | b2, c7.2 |
ch1 monoplexor ack |
33 | Note |
top dome |
dome wheel switches Note: from dome wheel box ctrl room above irig display |
34 | 430con |
c7 .5 |
on, off 430 power meter ch. 27may18 sband tx phase. was c9-4 -> c2-12 . c2-12 probably damaged when cable trolleys damaged cable. |
35 | 430con |
b7.6 |
ch1 power meter usb extender temporary patch 11may18 cable 9.5 now goes up here. sband tti dome transmit |
36 | 430con |
b7.7 |
ch power meter usb extender temporary patch 11may18 cable 9.5 now goes up here. sband tti dome receive |
C2 #'s @B2A |
description |
From |
1 |
sband card ds14 filament ready |
|
2 |
sband card ds13 kly1 mag ready |
|
3 |
bad(cable trolley accident) |
|
4 |
sband card ds15 hv ready |
|
5 |
sband card ds17 crowbarTrigFORcvA |
power supply B3 |
6 |
band card ds16 crowbarTrigFORcvB |
power supply B3 |
7 |
||
8 |
bad(cable trolley accident) | |
9 |
tti communications for dome. bad(cable trolley accident) |
B1,9.5 to B2a,2-9. not sure
the number at pwrsupply building 11may18 broken by cable tray trolleys now using C1.35,36 |
10 |
tti communications for dome bad(cable trolley accident) |
B1,9.6 to B2a,2-10. not sure
the number at the pwrsupply building see note 2.9 |
11 |
||
12 |
phase modulation |
from cable 9-4 27may18 now using c1-34.. c2-12 probably damaged when cable trolleys damaged fiber |
C3 | Description | From |
1 | pcWeather station to weather station. | B1- P1 |
C5 | From | To | Description |
1 | pb2 | b7-td12 | rs485 rx(master in pntcrate) to tx in td12 |
2 | pb3 | b7-td12 | rs485 tx master in pntcrate to rx in td12 |
3 | pb4 | b7-td12 | 1 second tick for tiedowns 12 |
4 | pb (black) |
b7-td12 |
1 sec tick for tiedown 8 |
5 | pb (yellow) |
b7-td12 |
1 sec tick for tiedown 4 |
6 | |||
7 | td8 tx rp1in dome tx removed nov17 |
||
8 | td8 rx rp1 removed nov17 | ||
9 | t4tx rp1 removed nov17 | ||
10 | t4rx rp1 removed nov17 | ||
11 |
|||
12 |
C5A | From |
To | Description |
1 | td12 dymec(bottom) | td4 | rs485 from td12 to td4 (not user which is tx/rx) |
2 | td12 dymec(bottom) | td4 | rsf85 from td12 to td4 |
3 | td12-5 Originally from C5.5 |
td4tick | 1 second tick for td4 |
4 | td4 dymec bottom | td8 via 5B.1 |
from td4, to to B7-12 then over to td8 via 5B1 this is how the 485 goes from td4 to td8 |
5 | td4 dymec bottom | td8 via 5B.2 |
see above |
6 | optical splitter B7-12 | td8tick | I'm not sure this really goes from td12 to 4 to 8... My guess is it goes directly from the optical splitter in td12 to td8 via C5B. |
7 | |||
8 | |||
9 | c5.9 |
td4 |
etherent rx at td4 |
10 | c5.10 |
td4 |
ethernet tx at td4 |
11 | |||
12 |
C5B | From |
To | Description |
1 | c5a:4 td4 dymec(bottom) | td8 | rs485 from td4 to td8.is looped back on c5a cable
from td4 |
2 | c5a:5 td4 dymec(bottom) | td8 | rs485 from td4 to td8.is looped back on c5a cable from td4 |
3 | td12-4 Originally from C5.4 |
td8tick | 1 second tick for td8 |
4 | |||
5 | |||
6 | |||
7 | |||
8 | |||
9 | c5.7 |
td8 |
ethernet rx at td8 |
10 | c5.8 |
td8 |
ethernet tx at td8 |
11 | |||
12 |
c7 |
From |
To |
Description |
1 |
c1-23 |
ch monoplexer driver |
|
2 |
c1-24 |
ch monoplexor ack |
|
3 |
noise ttl driver? |
||
4 |
noise ttl driver? |
||
5 |
b1.34 |
ch pwrmeter on/off |
|
6 |
b1.35 |
ch pwrmeter |
ch pwr meter ethernet |
7 |
b1.36 |
ch pwrmeter |
ch pwr meter ethernet |
8 |
|||
9 |
b1.26 |
430 tx lo blanking |
temp fiber when cable12 broke
(04nov13) |
10 |
|||
11 |
|||
12 |
b1-14 |
C8 | Description | From |
1 | datataking ethernet (rx @ pntp1) | C1.1 |
2 | datataking ethernet (tx @ pntp1) | C1.2 |
3 | ocu rs 422 link (tx @lcu) | C1.3 |
4 | ocu rs422 link (rx @ lcu) | C1.4 |
5 | irig signal | C1.5 |
6 | free .. was platform ethernet (rx @ lcu) rp2 failed
2006 |
RP2.tx7 |
7 | free .. was platform ethernet (tx @ lcu) rp2 failed
2006 |
RP2.rx7 |
8 | spare | |
9 | ||
10 | ||
11 | ||
12 |
C9 |
Description |
From |
1 |
tti transnet communications
for power supply tti modules Tested 16nov11, tx,rcv meter -15.4 dbm |
sband tti optic extender (by
sband console) |
2 |
tti transnet communications
for power supply tti modules Tested 16nov11. tx,rcv meter -15.6 dbm |
sband tti optic extender (by sband console) |
3 |
||
4 |
phase modulation |
to cable 2-12 27may18 now using c1-34. cable probably damaged when cable trolleys damaged cable |
5 |
tti transnet
communications for dome tti modules tested 16nov11: B1 to pwrSup patch: -16.1dbm B1 to B2a dome : -17.1 dbm B1 to ttiOpticExtender sband cab:-17.4dbm |
from sband console. Goes to
patch panel in power supply building and then up to dome box 2a #2-9 11may18 now using C1 35-36, cable trolleys broke cable 2. |
6 |
tti transnet communications
for dome tti modules tested 16nov11. tx,rcv meter B1 to pwrSup patch: -15.6 dbm B1 to B2aDome : -17.1 dbm B1 to ttiOpticExtender sband cab:-17.7 dbm |
from sband console. Goes to
patch panel in power supply building and then up to dome box
2a #2-10. see not 9.5 |
7 |
||
8 |
||
9 |
||
10 |
||
11 |
||
12 |
C11 multi mode 1-12 buffer 3 |
From |
To |
Description |
1 |
cal multiplexor rotary floor right blue cabinet separate fiber. |
pin 1 patch panel B11 |
Separate fiber cal mux
right blue cabinet to position 1 of patch panel B11 above 327 receiver. It this goes over to alfa to driver the ttl puls |
2 |
|||
3 |
|||
4 |
|||
5 |
B11.5 |
B?.5 |
alfa temps |
6 |
B11.6 |
B?.6 |
alfa temps |
7 |
B11.7 |
b?.7 |
alfa motor control |
8 |
B11.8 |
B?.8 |
alfa motor control |
9 |
B11.9 |
B |
alfa on/off switch |
10 |
|||
11 |
|||
12 |
rp2tx | Tx | Rx |
12 | P4.8 rot flr moveable dewar monitoring |
P4.7 rot flr moveable dewar monitoring. |
11 | B2.13->B1.13->RP1.5 (downstairs) | B2.12->B1.12->RP1.5 |
10 | P6.6 ->B13R.6-> tertiary(notused) | P6.9->B13R.9->tertiary(not used) |
9 | P6.10->B13R.10->B13L.1->B14.1 | P6.11->B13R.11->B13L.2->B14.2 servPlatform |
8 | free | |
7 | C8.6 -> vertex shelter | C8.7 -> vertex shelter |
Notes.. PC6 doesn't have enough fibers for the platform
ethernet to go to tertiary and the turret fixed
floor. We'll probably just run it to the tertiary. You can undo
the jumper in B13 if you want it at the turret fixed floor.
P4 | description | From |
1 | hpib extener tx | c1.11 |
2 | hpib extender rx (checked 27sep17) |
c1.18 |
3 | noise diode ttl pulse |
c1.14 changed 28sep17 This goes to transceiver then cal mulitplexor box (in right blue cabinet) |
4 | ?? | |
5 | noise diode ttl driver (not used??) | C1.14 (see p4.9) |
6 | noise diode ttl driver (not used??) | C1.15 (check order 14,15) |
7 | platform ethernet (rx @ floor) | RP2.tx12 |
8 | platform ethernet to lcu (tx @ floor) | RP2.rx12 |
9 |
bad 27sep17 was noise diode ttl pulse |
was to c1.14 ? |
PC 6 | description | B13R |
1 | Turret 485. Tx@tur from B2. 6 | 1 |
2 | Turret 485. Rx @ tur from B2.7 | 2 |
3 | tertiary ethernet (datataing) tx at ter. from B2.8 | 3 |
4 | tertiary ethernet (datataking) rx at ter. from B2.9 | 4 |
5 | 1 pps for tur and ter. (splitter in box 13) from B2.10 | 5 |
6 | platform ethernet (tur/ter) rcv From RP2.tx10 | 6 |
7 | bad cable (no connection B13.7 back) | 7 |
8 | bad cable (cable connected B13.8 back but no signal). | 8 |
9 | platform ethernet (tur/ter) tx. From RP2.rx10 | 9 |
10 | 430 dome power meter ethernet |
10 |
11 | 430 dome power meter ethernet |
11 |
12 | 430 pwr meter gregorian from B2.28 | 12 |
P7 | Description | From |
1 | platform ethernet (rx @ servPlat) | RP2.tx9->P6.10->B13R.10->B13L.1->B14.1 |
2 | platform ethernet (tx @ servPlat) | RP2.rx9->P6.11->B13R.11->B13L.2->B14.2 |
3 |
description | route | |
hilltop rfi monitor gpib | gpib fiber extender in pntcrate rack ->to PA11,13 -> to controlroom ->to M1,2 inputs fiber Junction box below junction box B1 -> junction box below water pipe patch box rightmost 2 input (looking from above).This junction box is behind the racks in the control room--> Up to rfi shack on hilltop. |