Num: |
frameSize 142 |
voltage U |
peakTorq 2 |
statorLen D |
speed 30/40 |
brake 1 |
connection type V |
Shaft Key A |
encoder type SA |
Inertia B |
Bolt Circle 165 |
Shaft diam 240 |
az |
142 |
460V |
2=std |
D |
30=3000rpm |
with |
v |
with |
sa |
A=std |
||
el |
142 |
460V |
2=std |
D |
40=4000rpm |
with |
v |
with |
sa |
A=std |
- drive,inverter specs, modules
- Emerson control technologies
- From Operation and maintenance manual, part 2 page 15.
component
el drive
(4u1)
azMaster
(4u3)
az slave
(4u4)
part #
sp2401
sp1406
sp1406
inpVoltage
range
380-480 vac
3phase
380-480 vac
3phase380-480 vac
3phasemaxOutput
current
15.3amps
11 amps
11amps
typical motor
output power
7.5KW
5.5KW
5.5KW
slot usage
slot 1
SM universal encoder
(5u2)
SM universal encoder
(7u2)
SM applications plus
(8u3)
ctnet node #=10
name=central processor
slot 2
SM application plus
(5u1)
ctnet node #=1
name=elevation processor
SM application plus
(7u1)
ctnet node #=3
name=azimuth
master processor
SM application plus
(8u1)
ctnet node #=4
name=azimuth
slave processor
slot 3
SM IO Plus
(5u3)
SM IO Plus
(7u3)
SM Ethernet
(8u2)
- Notes:
- (NuM) reference in schematics
- Most parameters in the drives are set on power up.
- See drive replacement (in manual) for those that need to be updated.