30jul01 plots
before motor installed (.ps) (.pdf)
01/09aug01
plots after the motors were installed (.ps). (.pdf)
These plots show the measured data for each day:
Plots of the change in pointing, gain, and sefd (.ps) (.pdf)Figure 1 is the Zenith angle pointing error in arc seconds versus za (top) and az (bottom). Figure 2 is the Azimuth angle pointing error in arc seconds (great circle) versus za (top) and az (bottom). Figure 3 is the pointing error plotted versus azimuth and zenith angle. The length of the arrow is proportional to the magnitude of the pointing error (1 tick mark equals 5 arc seconds). The direction of the arrow is the direction of the error. Figure 4 shows the beam squint (pointing error polA - pointing error polB). The plots top to bottom are: squint in za direction versus za, squint in az direction versus za, squint in za direction versus az, and squint in az direction versus az. Figure 5 is the gain in Kelvins/Jansky versus za (top) and azimuth (bottom). The fluxes were taken from chris salter's fits. A cal was fired at the beginning of each strip to convert to kelvins. Since each strip lasted up to 2 hours, the electronic gain of the system will vary with temperature. Using a single cal measurement will cause errors in the gain (probably a few percent). Figure 6 is the System Equivalent Flux Density (SEFD) in Janskies per Tsys. It only relies on the source flux so the electronic gain drift will not affect it.
The tertiary was positioned to +/- 5 arc seconds from before the motors were installed. We positioned the tertiary to the theoretical position rather than the position prior to the motor installation. We did this by:Figure 1 has the change in zenith angle pointing error (Before - after) in arc seconds versus az (top) and za (bottom). Figure 2 has the change in azimuth pointing error (before - after) in arc seconds versus az (top) and za (bottom). Figure 3 is the % change in gain (gainAfter/gainBefore - 1.)*100. Positive numbers mean the gain has gotten better. The gain for a particular strip can vary since there is only 1 cal measurement per strip. This will cause the ratio of strips between days to also vary. Figure 4 is the % change in SEFD (sefdBefore/sefdAfter-1.)*100. Positive numbers mean the performance has gotten better (the sefd decreased). Changes in this value come from the gain or the system temperature. Figure 5 is Tsys versus az (top), za (bottom) for both periods. * is before change, + is after.
processing: x101/010730/doit.pro, x101/010801/doit.pro
plotting : x101/010730/doplot.pro, x101/010801/doplot.pro,x101/010801/pltdif.pro
home_~phil