pin
on chip (see 190374 logical sheet) |
connects
to. |
description |
p5 crowbar heat lamp |
U41_p4 (4050B) |
|
p6 crowbar blower proof |
U41_p12 |
|
p7 hvps door proof |
U41_p15 |
|
p8 hvps grnd stick |
U41_p2 |
|
p16 Dome HV
ready(standby) |
E8 |
ActiveLo |
p38 hvps breaker status
(A) |
U60_p11 (sh4 AD) |
Active lo (output) |
p46 Reset pulse |
E13 (active lo) |
|
p48 (B) crowbar scr.
p48 is breaker coil. if not low more debugging |
U64_p5 (sh4 AF) |
active lo
(output) |
p51 (G) keep alive |
U64_p11 (sh4 AI) |
active lo (output) |
p67 hvps breaker closed |
U18_p12 (4050B) |
|
p68 hvps AC current |
U18_p4 |
|
p69 hvps DC current |
U18_p15 |
|
p77 crowbar trigger ps
proof |
E4 |
active lo |
p83 hvps oil |
U68_p6 |
For the venus runs in may12 the run was
stopped about once a day with the ground switch interlock (on the
faults page). Looking at the next page you could see
the hvps contactor open