rfi blankers
feb06
Bill sisk's radar blanker
manual (.pdf)
Terms:
-
rf pulse length: duration of transmitted pulse from radar
-
ipp: Inter Pulse period. The time from the 1st rf pulse
of a sequence
to the 1st rf pulse of the next sequence. During this time the
rf pulse
goes out and all of the echoes are returned.
Intro:
Radars are pulsed signals with low duty cycles.
An rf
pulse is transmitted and then the radar waits for the return echo.
At the
start of the next ipp another rf pulse is transmitted. The rf pulse
and
the echo's cause rfi in our receiver system.
A radar blanker synchronizes with the ipp of
a
radar and generates a blanking pulse that is high while the radar
rfi is
present in our system. This duration depends on how much multi path
scattering
and echoes there are.
The observatory has a radar blanker for the
airport
"FAA" radar and for the iridium satellites (they can be considered
radars
since they have an 50% uplink, downlink duty cycle). The
blanking
signals are sent to the interim correlator and to the wapps where it
temporarily
stops the lag accumulators.
Iridium blanker:
The
iridium signal has a 50% uplink/downlink duty
cycle (45
ms downlink, 45 ms uplink). Since there are no iridium phones near
the
observatory, only the downlink cycle causes rfi. Iridium has
supplied us
with a radar blanker that is synchronized with this 90 ms period. It
generates
a square output pulse.
The "blank" signal is currently the uplink
signal.
You must send the /blank signal to the blanker mux.
Radar blanker multiplexor:
This takes the iridium and faa blanking signals
and
multiplexes one of them to the interim correlator and wapp.
It is currently under test. It also contains the circuitry to extend
the iridium blanking signal.
Testing:
07feb06: radar multiplexor . calixto's box.
-
The iridium blank output from the iridium supplied box is synced
with the
uplink cycle. You must pass the /blank to the multiplexor
since we
want to blank the downlink (and positive is blank).
-
The front panel test point for the multiplexor can not drive 50
ohms. If
you plug a 50 ohm load into it, the blanking signals to the wapp
and the
interim correlator will fail. This needs to be buffered and a 50
ohm driver
added. Someone should also check the drivers to the wapp and the
interim
correlator.
-
The "modified iridium" mode is supposed to change the duty cycle
so that
more than 50% of the time is blanked. Currently the device is
making the
"positive" pulse narrower. This makes the blanking period
shorter, not
longer.
<-