FPGA System Monitor

The Kintex FPGA System Monitor measures several board power supplies and FPGA on−chip voltages. The System Monitor Measurement Ports table below lists the parameters measured by the System Monitor measurement ports and the required multiplication factors to apply to the readings (System Monitor ports VAUX5 to VAUX7 are not used in the Model 71861).

System Monitor Measurement Ports

Port

Parameter Measured

Measurement Scaling

VAUX0

VPWR (5 or 12V)

Voltage = VoltageReading x 14

VAUX1

3.3V

Voltage = VoltageReading x 4

VAUX2

1.2V MGT

Voltage = VoltageReading x 2

VAUX3

1.8V

Voltage = VoltageReading x 3

VAUX4

2.5V

Voltage = VoltageReading x 3

VAUX8

3.6V

Voltage = VoltageReading x 4

VAUX9

6V

Voltage = VoltageReading x 14

VAUX10

1.8V MGT

Voltage = VoltageReading x 3

VAUX11

1.0 MGT

Voltage = VoltageReading x 2

VAUX12

0.95V Core

Voltage = VoltageReading x 2

Use the System Monitor FPGA IP Core module to access these measurement ports.