The Kintex FPGA System Monitor measures several board power supplies and FPGA on−chip voltages. The System Monitor Measurement Ports table below lists the parameters measured by the System Monitor measurement ports and the required multiplication factors to apply to the readings (System Monitor ports VAUX5 to VAUX7 are not used in the Model
Port |
Parameter Measured |
Measurement Scaling |
VAUX0 |
VPWR (5 or 12V) |
Voltage = VoltageReading x 14 |
VAUX1 |
3.3V |
Voltage = VoltageReading x 4 |
VAUX2 |
1.2V MGT |
Voltage = VoltageReading x 2 |
VAUX3 |
1.8V |
Voltage = VoltageReading x 3 |
VAUX4 |
2.5V |
Voltage = VoltageReading x 3 |
VAUX8 |
3.6V |
Voltage = VoltageReading x 4 |
VAUX9 |
6V |
Voltage = VoltageReading x 14 |
VAUX10 |
1.8V MGT |
Voltage = VoltageReading x 3 |
VAUX11 |
1.0 MGT |
Voltage = VoltageReading x 2 |
VAUX12 |
0.95V Core |
Voltage = VoltageReading x 2 |
Use the System Monitor FPGA IP Core module to access these measurement ports.