12 meter communication timing

26mar10

Links:
Things to measure
The measurement program
The measurements
Summary


Intro

    Timing measurements for the communications with the 12meter controller was done on 26oct10. The setup was:
The Modbus communications uses the following steps:

    Times were measured for the individual steps as well as the total time for an operation. For each time measurement the program kept track of the:  min, max, sum , and sum of squares time duration. This allowed the final reporting of: avgTime, minTime, maxTime, and rmsTime.


Things to measure (top)


The measurement program:  (top)

The test program timed the following aspects of the communications:

The measurements: (top)

Total  times for measurement
Description
avg
min
max
rms
numTrys
Read 1 reg per call
8.03
6.09
9.62
0.22
867
Read 8 regs per call
12.41
10.49
14.63
0.60
100
Read State: 12 regs with 3 calls(5reg,2reg,5reg)
30.17
28.68
34.04
1.05
100
Read State: 1 call, 25 regs
21.50
19.02
25.52
1.60
100
Write 1 reg per call
8.39
7.51
10.95
.54
100



TABLE SHOWING BREAKDOWN  OF TIMING
READ 1 Register at a time. Cycle over all addresses
description
avg
min
max
rms
NumTrys
write hdr
0.01
0.01
0.02
0
867
read back hdr
8.01
6.08
9.59
0.22
867
readBack 1 reg
0.00
0.00
0.02
0.00
867
Total ReadTime 1 reg
8.03
6.09
9.62
0.22
867

Read 8 Registers at a time (23403-23410)
write hdr 0.01
0.01
0.02
0.
100
read back hdr 12.39
10.47
14.60
.69
100
readBack 8 reg 0.01
0.0
0.02
0.
100
Total ReadTime 8 reg 12.41
10.49
14.63
.60
100

Read Status,position,poserror,velocity,currents for azMaster,slave,Elevation
12 words using 3 reads: 5words@23683,2words@23693,5words@23703
write hdr 0.01
0.01
0.02
0.00
300
read back hdr 10.04
6.69
14.92
0.96
300
readBack 2 or 5 reg
0.01
0.00
0.02
0.00
300
Total ReadTime 12 words
30.17
28.68
34.04
1.05
100

Read Status,position,poserror,velocity,currents for azMaster,slave,Elevation
25 words 1 read:
25 words@23683
write hdr 0.01
0.01
0.02
0.00
100
read back hdr 21.48
18.99
25.49
1.59
100
readBack 25 reg 0.01
0.00
0.01
0.00
100
Total ReadTime 25 words 21.50
19.02
25.52
1.60
100

write single register @23404
write hdr + register
0.01
0.01
0.01
0.
100
read back hdr 8.37
7.49
10.92
.54
100
Total writeTime 1 word
8.39
7.51
10.95
.54
100

 

Summary:(top)

processing: svn/aosoft/p12m/testMultiReg.c, testRdSeg.c,testWrite.c,dump_adr.c

12meter page